| Node id | Title | Tier | Track | Duration | Verdict | Outcome |
|---|---|---|---|---|---|---|
| CM-COM-02 | Commissioning checks before power-up | Installer | Foundation | 2.86 min | REVISE | Use a commissioning checklist for the checks before power-up, in a safe order: isolation, mechanical and torque checks, DC polarity and voltage, then the dead tests. |
| CM-COM-05 | Charging the battery to full at commissioning | Installer | Foundation | 2.94 min | REVISE | Charge the battery to full at commissioning so that the battery monitor synchronises and the cells can balance, and record the result. |
| CM-COM-06 | Checking VRM monitoring before you leave the site | Installer | Foundation | 2.56 min | REVISE | Confirm that the site sends data to VRM, that the alarm rules are on, and that the client and the installer receive a test alarm before you leave the site. |
| CM-COM-08 | Commissioning first power-up and settings | Installer | Foundation | 2.79 min | ACCEPT WITH FIXES | Make the first power-up in the checklist order: close the battery connection with pre-charge, then update the firmware and enter and check the settings of each device. |
| CM-DOC-04 | Installation photo record | Installer | Foundation | 2.35 min | ACCEPT WITH FIXES | Take and file photos of each termination, label and serial number before the covers go on, so that warranty and service work has evidence. |
| CM-DOC-05 | Site service log | Installer | Foundation | 2.3 min | ACCEPT WITH FIXES | Record each later visit, firmware update and settings change in the site log with the date and the reason. |
| CM-HND-05 | Owner actions on a MultiPlus-II alarm | End user | Foundation | 2.8 min | ACCEPT WITH FIXES | Follow the owner action list for a low-battery, overload or grid-loss alarm, and tell when to call the installer. |
| CM-SIZ-06 | Sizing for battery current limits | DIY | Foundation | 2.99 min | ACCEPT WITH FIXES | Check that the battery and BMS discharge limit covers the peak inverter current, and that the charge limit covers all chargers at the same time. |
| CM-WAR-01 | Victron warranty and the dealer path | Installer | Foundation | 2.76 min | ACCEPT WITH FIXES | Tell what the Victron product warranty covers, and that a claim goes through the dealer that sold the product. |
| DG-BAT-02 | Troubleshooting early charge stop from BMS limits | Installer | Foundation | 2.84 min | ACCEPT WITH FIXES | Read the BMS CVL and CCL on the GX and decide whether a BMS limit, cell imbalance, low temperature or a driver default stops charging early. |
| DG-EC-01 | Fault indications on Victron products | End user | Foundation | 2.69 min | ACCEPT WITH FIXES | Find where a Victron product shows its state and its faults: unit LEDs, display, VictronConnect, GX notifications and VRM. |
| DG-EC-02 | Looking up a code in the official error list | DIY | Foundation | 2.29 min | ACCEPT WITH FIXES | Find the official Victron error code page for a product family and read the cause and the action for a code. |
| DG-EC-05 | Reading VE.Bus error codes on a GX device | DIY | Foundation | 2.95 min | ACCEPT WITH FIXES | Read the VE.Bus error number on a GX or in VictronConnect and look up its meaning. |
| DG-EC-07 | Troubleshooting VE.Bus error 8 | Installer | Foundation | 2.98 min | ACCEPT WITH FIXES | Find why the ground relay test fails (VE.Bus error 8) by checking the neutral-earth wiring on AC-out. |
| DG-EC-08 | Troubleshooting VE.Bus communication errors in multi-unit systems | Installer | Foundation | 2.94 min | REVISE | Find the cause of a VE.Bus communication error in a parallel or three-phase system: a cable, mixed firmware or a missing unit. |
| DG-EC-10 | Troubleshooting low battery shutdown when a lithium battery looks full | Installer | Foundation | 2.99 min | REVISE | Find why a MultiPlus shuts down on low battery while the lithium battery is full: shutdown levels, cable voltage drop or a BMS discharge limit. |
| DG-EC-11 | Troubleshooting high temperature alarms | DIY | Foundation | 2.69 min | ACCEPT WITH FIXES | Find the cause of a high temperature alarm on an inverter/charger: airflow, ambient temperature, load or a loose connection. |
| DG-EC-12 | Troubleshooting rejected generators | Installer | Off-grid | 2.6 min | REVISE | Find why a MultiPlus does not accept a generator: voltage or frequency window, input current limit or the weak-AC setting. |
| DG-EC-14 | Reading MPPT LED codes | DIY | Foundation | 1.89 min | REVISE | Read the bulk, absorption and float LEDs of an MPPT and tell a normal charge state from an error blink pattern. |
| DG-ESS-01 | Troubleshooting ESS grid metering | Installer | ESS / grid | 2.85 min | REVISE | Find a grid meter in the wrong role or position, or a CT on the wrong phase or in the wrong direction, from the GX power values. |
| DG-ESS-02 | Troubleshooting ESS that does not discharge | Installer | ESS / grid | 2.86 min | ACCEPT WITH FIXES | Find why an ESS does not discharge: minimum SoC, the BatteryLife limit, the grid setpoint, a BMS discharge limit or a charge schedule. |
| DG-ESS-03 | Troubleshooting ESS grid reconnect | Installer | ESS / grid | 2.98 min | ACCEPT WITH FIXES | Read why an ESS stays disconnected after a grid outage from the grid code limits and the GX status. |
| DG-ESS-04 | Troubleshooting Dynamic ESS decisions | Installer | ESS / grid | 2.55 min | REVISE | Read the Dynamic ESS schedule and forecast in VRM and tell whether wrong inputs or loads that VRM cannot see cause an unexpected decision. |
| DG-FW-01 | Troubleshooting interrupted VE.Bus firmware updates | Installer | Foundation | 2.91 min | ACCEPT WITH FIXES | Recover a VE.Bus unit after an interrupted firmware update and load the saved settings again. |
| DG-GEN-02 | Telling active errors from history errors | DIY | Foundation | 2.27 min | ACCEPT WITH FIXES | Tell an active error from an error in the history and decide which one needs action. |
| DG-GEN-05 | Troubleshooting system faults one part at a time | Installer | Foundation | 2.94 min | ACCEPT WITH FIXES | Isolate a fault by checking one part at a time (supply, battery, communication, settings) and changing one thing at a time. |
| DG-GEN-07 | Troubleshooting AC leakage in the loads | Installer | Foundation | 2.77 min | REVISE | Find an AC-out load with neutral-earth leakage by disconnecting the loads one at a time. |
| DG-GEN-08 | Collecting evidence for support | Installer | Foundation | 2.91 min | ACCEPT WITH FIXES | Collect the firmware versions, settings files, VRM portal ID, error history and photos that a dealer needs to handle a fault. |
| DG-GX-01 | Troubleshooting devices missing from GX | DIY | Foundation | 2.69 min | ACCEPT WITH FIXES | Find why a VE.Direct or USB device is missing from the GX: port limits, a power-only USB port, the cable or the device setting. |
| DG-GX-03 | Troubleshooting missing VRM notifications | DIY | Foundation | 2.64 min | ACCEPT WITH FIXES | Find why VRM alarm notifications stop: a muted rule, a phone not enabled for the site, or rate limiting after many alarms. |
| DG-GX-04 | Troubleshooting add-ons after a Venus OS update | Installer | Foundation | 2.34 min | REVISE | Find a Node-RED flow or a community driver that stops working or overrides the BMS after a Venus OS update. |
| DG-GX-05 | Restarting and resetting GX device | Installer | Foundation | 2.96 min | ACCEPT WITH FIXES | Recover a GX device that does not start or is locked, first by a restart and then by a reset to factory settings. |
| DG-GX-06 | Troubleshooting VictronConnect Bluetooth connections | DIY | Foundation | 2.77 min | ACCEPT WITH FIXES | Find why VictronConnect cannot connect over Bluetooth: an old phone pairing, a wrong PIN, Bluetooth turned off on the device, or the Windows app. |
| DG-GX-07 | Troubleshooting MK3-USB connections to VE.Bus products | Installer | Foundation | 2.96 min | REVISE | Find why VEConfigure or VictronConnect cannot reach a VE.Bus unit: a GX on the same bus, the COM port, an iOS phone or the MK3 driver. |
| DG-MM-01 | Troubleshooting Orion DC-DC low output | DIY | Mobile | 2.98 min | REVISE | Find why an Orion DC-DC charger gives no or low output: engine detection levels, input cable voltage drop, the negative path or the unit state shown by its LEDs. |
| G01 | Troubleshooting MPPT with no charge current | Not set | Not set | 2.99 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G03 | Connecting MPPT in the safe order | Not set | Not set | 2.9 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G04 | Troubleshooting MPPT errors after a firmware update | Not set | Not set | 2.22 min | ACCEPT | Outcome not in graph. |
| G05 | Troubleshooting charger error 67 | Not set | Not set | 1.75 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G08 | Troubleshooting CAN battery detection on Cerbo GX | Not set | Not set | 2.93 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G15 | Configuring battery monitor on Cerbo GX | Not set | Not set | 2.98 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G16 | Configuring lithium charge settings on MPPT | Not set | Not set | 2.94 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G19 | Troubleshooting VE.Bus error 11 | Not set | Not set | 2.96 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G20 | Troubleshooting RCD trips on a MultiPlus-II | Not set | Not set | 2.96 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G23 | Troubleshooting MultiPlus-II overload and DC ripple alarms | Not set | Not set | 2.96 min | REVISE | Outcome not in graph. |
| G27 | Configuring ESS grid codes | Not set | Not set | 2.96 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G30 | Updating Victron firmware safely | Not set | Not set | 2.96 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G36 | Troubleshooting Phoenix restarts and LED codes | Not set | Not set | 2.98 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G37 | Sizing DC cables and fuses | Not set | Not set | 3.02 min | ACCEPT WITH FIXES | Outcome not in graph. |
| G38 | Connecting AC and DC cables with good workmanship | Not set | Not set | 2.99 min | ACCEPT WITH FIXES | Outcome not in graph. |
| PH-004 | Cable sizes in mm2 and AWG | DIY | Foundation | 2.22 min | ACCEPT WITH FIXES | Read a cable cross-section in mm2 or AWG from the cable print and convert between the two with a table. |
| PH-010 | Connecting cables to paralleled inverter/chargers | Installer | Foundation | 2.86 min | REVISE | Make the DC and the AC cables to each paralleled inverter/charger the same length and cross-section, torque every connection to the same value, and do not over-dimension the AC cables. |
| PH-015 | Cable lugs: selection | DIY | Foundation | 1.68 min | ACCEPT WITH FIXES | Choose a cable lug that matches both the cable cross-section and the stud diameter of the terminal. |
| PH-023 | Connecting VE.Bus and VE.Can data cables | DIY | Foundation | 2.98 min | REVISE | Use factory-made straight UTP cables for VE.Bus and VE.Can, never crossover cables, and label any cable with a special BMS pinout. |
| PH-024 | Connecting small signal wires | DIY | Foundation | 2.86 min | REVISE | Terminate small signal wires (remote on/off, relay contacts, temperature sensor) in pluggable terminal blocks with the correct wire size and a ferrule where needed. |
| PH-027 | Installing Lynx busbar strings | DIY | Foundation | 3 min | ACCEPT WITH FIXES | Join Lynx modules (Power In, Shunt, Smart BMS, Distributor) in the order of the system design and torque the busbar joints to the manual value. |
| PH-029 | Installing covers on busbars and Lynx modules | DIY | Foundation | 2.87 min | REVISE | Fit the covers or insulating boots on busbars, fuse holders and battery terminals before you leave the work area. |
| PH-035 | Installing battery temperature sensors | DIY | Foundation | 2.97 min | ACCEPT WITH FIXES | Fit a battery temperature sensor (Smart Battery Sense, shunt temperature input or charger sensor) on the battery terminal or case where the maker specifies. |
| PH-038 | Installing DC cable runs | DIY | Foundation | 1.96 min | ACCEPT WITH FIXES | Protect a cable run from chafe and strain with supports at intervals and with grommets or glands where it passes through a panel. |
| PH-045 | Connecting PV strings | DIY | Foundation | 2.99 min | REVISE | Connect PV modules into the series strings and parallel groups that the design shows. |
| PH-047 | Connecting Orion DC-DC charger cables | DIY | Mobile | 2.97 min | ACCEPT WITH FIXES | Run and terminate the input and output cables of an Orion DC-DC charger between the starter and house batteries, with a sound negative return path. |
| PH-050 | Installing energy meter current transformers | Installer | ESS / grid | 2.49 min | REVISE | Fit the current transformers of an energy meter on the correct conductor of each phase, with the arrow in the direction of power flow that the manual gives. |
| PH-052 | Connecting inverter/charger remote on/off | DIY | Foundation | 2.99 min | REVISE | Wire a BMS or BatteryProtect signal to the remote on/off terminals of an inverter/charger, and leave the unit switch on, because the remote input works only then. |
| PR-ESS-12 | Testing ESS operation at commissioning | Installer | ESS / grid | 2.47 min | ACCEPT WITH FIXES | Test grid setpoint tracking, the feed-in limit and the change-over on loss of mains before you hand over an ESS site. |
| PR-GX-14 | Monitoring Orion DC-DC chargers on GX | Installer | Mobile | 2.94 min | ACCEPT WITH FIXES | Show the energy of an Orion DC-DC charger correctly on a GX, with a shunt set as a DC energy meter when the Orion has no data port. |
| PR-VC-03 | Configuring PIN codes in VictronConnect | DIY | Foundation | 1.72 min | ACCEPT WITH FIXES | Change the Bluetooth PIN of a Smart device and reset a lost PIN with the PUK code from the product label. |
| SF-003 | PV array voltage in daylight: safety | End user | Foundation | 2.01 min | ACCEPT WITH FIXES | Treat a PV array and its cables as live in daylight, because the modules cannot be switched off. |
| SF-004 | Protective equipment for battery work: safety | DIY | Foundation | 2.36 min | REVISE | Remove metal jewellery and wear eye protection and suitable gloves before you work on batteries. |
| SF-014 | Commissioning inverter pre-charge with a BMS | DIY | Foundation | 2.5 min | ACCEPT WITH FIXES | Pre-charge the input capacitors of an inverter before the main DC connection closes, with a resistor or the pre-charge function of the BMS, as the manual describes. |
| SF-018 | Battery bank short circuit current: safety | DIY | Foundation | 1.91 min | REVISE | Find the prospective short-circuit current of a battery bank from the battery data sheet or from the battery maker. |
| SF-021 | Sizing branch circuit fuses | DIY | Foundation | 2.96 min | REVISE | Fuse each branch circuit at the distribution point so that the fuse protects the smaller branch cable. |
| SF-023 | Installing Orion DC-DC charger fuses | DIY | Mobile | 2.59 min | ACCEPT WITH FIXES | Fuse both the input cable and the output cable of a DC-DC charger, because each cable connects to a battery. |
| SF-025 | Installing DC circuit breakers | DIY | Foundation | 2.88 min | ACCEPT WITH FIXES | Fit a DC circuit breaker rated for DC and the system voltage, and install a polarised breaker in its marked current direction. |
| SF-026 | BatteryProtect with inverters: safety | DIY | Foundation | 2.71 min | REVISE | Switch an inverter off through its remote on/off input from a BatteryProtect, and never put the BatteryProtect in the inverter DC feed. |
| SF-046 | Disconnecting PV connectors: safety | DIY | Foundation | 2.89 min | REVISE | Open a PV circuit with its isolator or by stopping the MPPT, and never by pulling a PV connector apart while current flows. |
| TH-3P-01 | AC supply systems: types | DIY | Foundation | 2.44 min | ACCEPT WITH FIXES | Name single-phase, split-phase and three-phase supplies, and give the phase-to-neutral and phase-to-phase voltages of each. |
| TH-3P-06 | Split-phase systems: theory | Installer | Foundation | 2.35 min | REVISE | Tell how two inverter/chargers or an autotransformer make a 120/240 V split-phase supply, and which loads a 120 V-only source can supply. |
| TH-AC-01 | AC voltage and frequency: theory | End user | Foundation | 1.86 min | ACCEPT WITH FIXES | Tell AC from DC, and name the RMS voltage and the frequency of the local mains supply. |
| TH-AC-04 | AC conductors: types | End user | Foundation | 2.08 min | ACCEPT WITH FIXES | Name the line, neutral and protective earth conductors of an AC circuit, tell the job of each, and tell which ones carry current in normal use. |
| TH-ACC-02 | AC PV on the inverter output: theory | Installer | Foundation | 2.89 min | REVISE | Tell why an AC-coupled PV inverter goes on the AC output of the inverter/charger in an off-grid or backup system, and what goes wrong on the AC input. |
| TH-ACC-04 | AC PV power limit: theory | Installer | Foundation | 2.9 min | ACCEPT WITH FIXES | Tell why the AC-coupled PV power must not be more than the inverter/charger power (the 1:1 rule). |
| TH-ACC-06 | ESS grid setpoint: theory | Installer | ESS / grid | 2.78 min | REVISE | Tell how ESS measures the power at the grid connection and changes the inverter/charger power to hold the grid setpoint, and read the sign of import and export. |
| TH-ACC-08 | Minimum battery capacity for AC PV: theory | Installer | Foundation | 2.4 min | ACCEPT WITH FIXES | Calculate the minimum battery capacity that a given AC-coupled PV power needs. |
| TH-BAT-05 | Battery charge efficiency: theory | DIY | Foundation | 2.89 min | REVISE | Tell why a battery needs more charge in than it gave out, and compare the charge efficiency of lead-acid and lithium. |
| TH-BAT-06 | Internal resistance and voltage sag: theory | DIY | Foundation | 2.99 min | ACCEPT WITH FIXES | Tell why battery voltage falls under a heavy load and rises during charge, and why the effect is smaller in a lithium battery. |
| TH-BAT-08 | Battery temperature effects: theory | End user | Foundation | 1.84 min | REVISE | Tell how cold reduces the available capacity and how heat shortens the life of lead-acid and lithium batteries. |
| TH-BAT-09 | Lithium charging in the cold: theory | DIY | Foundation | 2.99 min | REVISE | Tell why a lithium iron phosphate battery must not charge below its low-temperature limit, and why every charger on it then needs a temperature source. |
| TH-BAT-10 | Battery voltage and state of charge: theory | End user | Foundation | 2.56 min | ACCEPT WITH FIXES | Tell why rest voltage is a fair guide to the state of charge of a lead-acid battery but not of a lithium iron phosphate battery, whose voltage curve is flat. |
| TH-BAT-15 | Cell imbalance: theory | DIY | Foundation | 2.96 min | ACCEPT WITH FIXES | Tell how one cell at a high voltage makes a BMS stop the charge before the battery pack reaches its set voltage. |
| TH-CHG-04 | Temperature compensation: theory | DIY | Foundation | 2.78 min | ACCEPT WITH FIXES | Tell why the charge voltage of a lead-acid battery must fall as the battery temperature rises, and why a lithium battery needs no temperature compensation. |
| TH-CHG-05 | Lithium charge profile: theory | DIY | Foundation | 2.94 min | REVISE | Tell how a lithium iron phosphate charge profile differs from a lead-acid profile: lower absorption voltage, short absorption, float near rest voltage and no temperature compensation. |
| TH-CHG-06 | Battery charge current limit: theory | DIY | Foundation | 2.96 min | ACCEPT WITH FIXES | Calculate the maximum charge current of a battery bank from its C-rate and its BMS limit, and check that the sum of all chargers stays below it. |
| TH-CHG-08 | Charger voltage sense: theory | DIY | Foundation | 2.78 min | REVISE | Tell why a charger measures a higher voltage than the battery terminals during charge, and how a shared battery voltage sense corrects it. |
| TH-DC-01 | Voltage, current and resistance: theory | End user | Foundation | 2.05 min | ACCEPT WITH FIXES | Name voltage, current and resistance with their units, and tell which one a meter measures across a part and which one it measures through a part. |
| TH-DC-02 | the voltage-current-resistance law: theory | DIY | Foundation | 2.21 min | ACCEPT WITH FIXES | Calculate the current, the voltage or the resistance in a DC circuit when the other two values are known. |
| TH-DC-03 | Electrical power: theory | End user | Foundation | 2.06 min | ACCEPT WITH FIXES | Calculate the power of a DC load from its voltage and current, and calculate its current from its power and voltage. |
| TH-DC-04 | Power and energy: theory | End user | Foundation | 1.86 min | ACCEPT WITH FIXES | Tell power in watts from energy in watt-hours, and calculate the energy that a load uses in a given time. |
| TH-DC-05 | Amp-hours and watt-hours: theory | End user | Foundation | 1.9 min | ACCEPT WITH FIXES | Convert a battery capacity in amp-hours to watt-hours at the nominal battery voltage, and compare the energy of two batteries with different voltages. |
| TH-DC-07 | Cable resistance: theory | DIY | Foundation | 1.94 min | ACCEPT WITH FIXES | Tell how the resistance of a copper cable changes with its length and with its cross-section. |
| TH-DC-08 | Power loss in cables and connections: theory | DIY | Foundation | 2.18 min | ACCEPT WITH FIXES | Calculate the power that a cable or a connection turns into heat from its current and resistance, and show that double the current gives four times the loss. |
| TH-INV-02 | Inverter battery current: theory | DIY | Foundation | 2.86 min | ACCEPT WITH FIXES | Calculate the battery current that an inverter draws for a given AC load, efficiency and battery voltage. |
| TH-INV-10 | Capacitor inrush current: theory | DIY | Foundation | 2.24 min | REVISE | Tell why the input capacitors of an inverter draw a very large current for a moment when a battery connects to them, and why that current makes a spark at the terminal. |
| TH-PV-05 | Sizing PV strings for cold-day voltage | DIY | Foundation | 2.53 min | ACCEPT WITH FIXES | Calculate the open-circuit voltage of a PV string on the coldest expected day from the module temperature coefficient. |
| TH-PV-07 | MPPT ratings: theory | DIY | Foundation | 2.7 min | ACCEPT WITH FIXES | Read the maximum PV voltage, the maximum PV short-circuit current and the rated charge current of an MPPT, and tell what happens when the array is larger than these ratings. |
| TH-SYS-01 | Victron system parts for owners | End user | Foundation | 2.72 min | ACCEPT WITH FIXES | Name the job of each part of a Victron system (battery, inverter/charger, solar charger, battery monitor and GX device) and the charge states that a display shows. |
Outcomes come from the graph. 15 module ids have no graph node. Their outcomes are not available here. Verdicts record the draft review.